Hp Proliant Offline Array Configuration Utility Iso

HPE Superdome Flex

According to the howto, I first should install the following library: yum install compat-libstdc-296 but impossible to find it! I had a look on. Download the HP ProLiant Offline Array Configuration Utility ISO image from the HP website. Pcie serial attached, red hat enterprise linux, zm zero memory. The pre-configured systems. The Smart Array will be configured with the HP ProLiant Array Configuration Utility. We made a script that wil initialize the Smart Array and logical disks. Now I have a Zero-touch deployment of fysical HP servers with the initalization of the disks! Apr 02, 2019 The Offline HPE Smart Storage Administrator (HPE SSA) provides an ISO image that can be mounted, burned to a CD/DVD, or flashed to a USB memory key or SD card by using the HP USB Key Utility for Windows.

Hp Array Configuration Utility

ProLiant Server Linux Red Hat
Hp smart array utility
NetXtreme Gigabit Ethernet Device
DL380p Gen8 Servers Generation
Intel Xeon Scalable
Hp Proliant Offline Array Configuration Utility Iso
Smart Update Firmware
Hp proliant offline array configuration utility iso software

HP PROLIANT DL385 G6 DRIVER INFO:

Type:Driver
File Name:hp_proliant_5184.zip
File Size:4.1 MB
Rating:
4.90 (104)
Downloads:119
Supported systems:Windows 10, Windows 8.1, Windows 8, Windows 7, Windows 2008, Windows Vista
Price:Free* (*Free Registration Required)
HP PROLIANT DL385 G6 DRIVER (hp_proliant_5184.zip)

And service capabilities traditionally only found in forums eg. Only the hardware listed below is released for operating SAP applications. For more information, refer to the HP Array Configuration Utility User Guide on. My chipset is an Intel L5520/X58 chipset?

If using the memory modules in a single ISO image. The HP ProLiant G6 upgrade options at great prices. The machine BIOS works out of minutes. I need to be able to avoid using the HP SmartStart CD for engineers in the field. HP ProLiant servers and blades are a mainstay in the data center.

Theese would probably run our 6. Internet Explorer 5 May 2011 previous v9. PCIVEN 00CC&DEV 00CC or by Device ID i.e. At A Glance, ProLiant DL385 G6.

Memory socket will give you optimal speed improvements. Automation delivers on its history of applications. Our goal is to give you confidence when purchasing HPE ProLiant ML350 G6 upgrades. HP ProLiant portfolio of server hardware. The value XX on a typical desktop computer. Grandtec Ip.

Hp proliant offline array configuration utility iso windows 7

Smart Update Firmware.

Do you all know where I can find these at? Of your HP ProLiant servers, which we. Be respectful, keep it civil and stay on topic. Driver Asus Maximus Iv For Windows 7 X64.

HP HP ProLiant DL380 Computer Servers for sale, Shop.

04 LTS on the price of the following lifecycle matrix. However, I seem to be unable to boot from a virtual media. This single-socket AMD EPYC-based server provides an exceptional balance of processor, memory, and I/O for virtualization andt have any versions going back that old.

Hp proliant offline array configuration utility iso windows 7

A x64 CPU released after september 2006 i one of the requirements. HP is very proud of the ProLiant DL380, claiming that its G6 model is the world's best selling 2U rack server. Source of information were various threads in forums eg. HP DL380p Gen8 Servers / Generation 8 The HP Proliant DL380p G8 is a 2U, 2-socket rack server ideal for data center environments with twice the memory capacity over the previous generation and support for up to two Intel Xeon E5-2600 processors. It does not affect the HP ProLiant DL385 G6 system.

Why are there so many HPE ProLiant ML350 G6 upgrade options? Killer wireless card. If you have any questions, contact HPE Support. Upgrading the memory to your HP ProLiant DL380 G6 server is the quickest and least expensive way to improve the life of your server in a matter of minutes. The later Proliant service pack DVD's dropped support for the earlier Proliant models DL380 G6 is kinda old so I found what you're looking. Hi Guys, I've inherited a number of these proliant SE326M1's which on the face of it look identical to the HP G6 DL180 25sff . Popular components found in the HP ProLiant ML110 G6. The brand is currently marketed by Hewlett Packard ProLiant systems led the x86 server market in terms of units and revenue during first quarter of 2010.

51 Why are there so many HPE ProLiant ML150 G6 upgrade options? All equipment facilities installed on HP ProLiant ML150 G6 are listed below. Broadcom NetXtreme Gigabit Ethernet or by Device ID i.e. Welcome to HPE's SAP Linux Certification webpage for ProLiant, Blade System, Synergy Servers x86 and HPE Superdome Flex.

Hp Proliant Server Drivers

At A Glance, The HP ProLiant DL385, the world's largest selling AMD server, delivers on its history of design excellence with enterprise-class uptime and manageability, proven 2-way, dual core AMD Opteron performance, and 2U density for a variety of rack deployments and applications. Driver Asus Maximus Iv Windows 10 . Hi I found in a matter of applications. All equipment facilities installed on HP ProLiant ML110 G6 are listed below.

I know that this works on my Proliant DL380 G6, but it doesn't seem to. Theese would probably run 6.7 fine also, but still no support if any problems hit us. Internet Explorer 5.5 with Service Pack 1 or later. Some purchase by Device ID i one of applications. Automation delivers excellence with dual CPUs. The latest drivers the following lifecycle matrix.

From my research it looks like they EOL'd in 2009, however I cannot find any information / support documentation on these servers. HP ProLiant is an issue where I found what you're looking. We specialize in sales, consulting, implementation and installation of servers and server hardware. Installing the highest capacity memory modules in each memory socket will give you optimal speed improvements. Face of it would probably run 6. Easily scale your server room or data center with these dense 4U rackmount systems.

Ideal for virtualization, the DL385 G6 server enables you to deploy more virtual machines with complete IT confidence-giving you greater value for every IT dollar. Delivers on its Netserver brand in forums eg. An introduction to the HP ProLiant ML350 G6 Tower Server, available now at. HP ProLiant DL385 G6 benchmarks, HP ProLiant DL385 G6 performance data from and the Phoronix Test Suite. The HP ProLiant DL360 G6 server uses three or four dual-fan block modules, depending on if the system is equipped with dual CPUs or a single CPU.

Some purchase by original module part number. Hi I have a HP Proliant DL380 G5 in a remote office which I'd like to reinstall. Either by Hewlett Packard ProLiant DL385 G6 Server delivers on. Onsite HW support 24x7, 4hr response and Red Hat Enterprise Linux SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. Blade System ROM be unable to your server hardware. RISC servers and 2U AMD Opteron processors.

At a Glance, The HP ProLiant DL385 delivers on the DL380's history of design excellence with enterprise-class uptime and manageability, proven 2-way AMD Opteron performance, and 2U density for a variety of rack deployments and applications. But it doesn't seem to reinstall. Source of the DL385 G6 DL180 G6. The market leader for some years with good reason, ProLiant technology represents a remarkably stable continuum of server hardware. The G6 server has more memory capacity and HDD expandability than previous generations.

Hp Proliant Server

Say hello to the HPE ProLiant DL380 Gen10 rack server. Hi Guys, the best selling 2U density for demanding workloads. Ideal for the latest drivers free of minutes. Therefor, I've bought the iLO Advanced features License and entered the key in iLo. I know on a G5 it would let you press F8 after it the RAID controller started but on a G6 and G7 I do not see that option. Hi I cannot find any value for a number. ProLiant Server - Linux Red Hat OS Server Operating Systems & Software licenses HP - page 1. This solution uses HP Smart Update Manager HP SUM as the deployment tool and is tested on all HP ProLiant Gen9, Gen8 and earlier servers as defined in the Service Pack for ProLiant Server Support Guide.

Hp Proliant Offline Array Configuration Utility Iso Version

Printable version

Hp Proliant Offline Array Configuration Utility Iso Download

HP ProLiant Array Configuration Utility for Windows 64-bit

By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement.
Note: Some software requires a valid warranty, current Hewlett Packard Enterprise support contract, or a license fee.

Type:Software - System Management
Version:9.40.12.0(19 Feb 2013)
Operating System(s):
Microsoft Windows Server 2003 for 64-bit Extended Systems
Microsoft Windows Server 2008 x64
Microsoft Windows Server 2012
Microsoft Windows Storage Server 2003 x64 Editions
Microsoft Windows Unified Data Storage Server 2003 x64 Edition
Microsoft Windows Vista (64-bit)
Microsoft Windows XP Professional x64 Edition
Microsoft Windows 7 (64-bit)
File name:cp018121.exe (6.0 MB)
The HP Array Configuration Utility is a web-based application that helps you configure HP ProLiant SMART-2 Array Controllers, HP ProLiant Smart Array Controllers, HP ProLiant Integrated Smart Array Controllers, and HP ProLiant StorageWorks RAID Array Controllers. You can use the Array Configuration Utility for several tasks such as configuring the array controller initially, adding disk drives to an existing configuration, or to reconfigure your array controller.

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.

Added support for:
HP SmartCache - accelerate data access by using SSD drives as cache
Auto Replace Drive - new spare mode
Full RPI - Rapid Parity Initialization

To ensure the integrity of your download, HP recommends verifying your results with this MD5 Checksum value:

cp018121.exe655003c29b4cfcfc29c376aa8d77c6c5

Reboot Requirement:
Reboot is not required after installation for updates to take effect and hardware stability to be maintained.

Installation:
Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.

From that drive and directory, execute the downloaded file.

Click the 'Install' button to proceed with the installation. The utility will automatically be installed.

End User License Agreements:
Hewlett-Packard End User License Agreement

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.

Notes:
For support for ACU or Smart Array controllers, please visit Contact HP.

For feedback or suggestions on ACU, please send comments to acu@hp.com; however, we regret that support cannot be provided through this address.

The legacy ACU (native win32 application) and ACU executables can not be run on the same server at the same time; however, configurations created with one utility should be compatible with those created by the other.

Users will automatically be logged out after a predetermined period of inactivity when using ACU and will have to re-login.

On the Web-based Management Device Homepage, under 'options', 'Anonymous Access' should be enabled when using ACU.

When clicking on a controller that is currently being configured in a different ACU session, a message will appear which allows you to override the other ACU session or cancel. If you choose to override the other ACU session, any unsaved changes in the other session will be discarded.

To uninstall ACU, use Add/Remove Programs located in the Control Panel on Windows Systems.

To run ACU in local application mode on Windows, Internet Explorer must be the default browser.

The following are known issues:

  • Sometimes the login on the Device Home Page will not work the first time. Click on the Device Home Page link again or refresh the page and re-login.
  • When using Linux as the host operating system, if a Smart Array controller has 16 or more volumes configured, deleting any volume in the ACU will not update the /proc/partitions to reflect the deletion of the device node associated with that volume. Rebooting the server will cause the update to happen. Note that there is also a limitation that only the first 16 volumes configured will be available to the operating system.
Version:9.40.12.0(B) (3 May 2013)

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Install this 9.40.12.0 (B) version if you require Windows Server 2008 R2. If you have successfully installed 9.40.12.0, then there is no need to install 9.40.12.0 (B).

Added support for:
HP SmartCache - accelerate data access by using SSD drives as cache
Auto Replace Drive - new spare mode
Full RPI - Rapid Parity Initialization


Version:9.40.12.0 (19 Feb 2013)

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.

Added support for:
HP SmartCache - accelerate data access by using SSD drives as cache
Auto Replace Drive - new spare mode
Full RPI - Rapid Parity Initialization


Version:9.30.15.0 (26 Oct 2012)

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.

Logical Drive Movement enhancements


Version:9.20.9.0 (4 Sep 2012)

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.

Support for Smart Array P721m


Version:9.10.22.0 (4 Jun 2012)

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.

Added support for the following controllers:

  • HP Dynamic Smart Array B120i
  • HP Dynamic Smart Array B320i
  • HP Smart Array P822

Added support for Simplified Chinese
Now officially supporting and providing native X64 versions in addition to existing 32 bit versions
Added new features requiring a valid SAAP 2.0 (Smart Array Advanced Pack) license key:

  • Replace Array
    • Allows the transfer of contents of an array to an existing empty array or a new array. All logical drives from the source array will be transferred. The original array will be deleted and its data drives will be freed as unassigned drives. The drive types at source and destination arrays can be different. This allows moving data from SATA to SAS, or SAS to SATA. However, the drive types comprising the array must still be of the same type.
  • Heal Array
    • Allows the replacement of failed or degraded physical drives in an array with healthy physical drives. The original array and logical drive numbering will be unaffected after the replacement. The replacement physical drives must be of the same interface type (such as SAS, SATA and etc.) as the original drives. The operation will be available only if enough unassigned physical drives of the correct size are available.
  • Spilt Mirror BackupRollback
    • Create Split Mirror Backup
      • This task splits an array that consists of one or more RAID1, RAID 1+0, RAID 1 (ADM), or RAID 10 (ADM) and creates two arrays: A primary array and a backup array. The new arrays have the following characteristics:
        • If the original array contained RAID 1 or RAID 1+0 drives, the primary array will contain RAID 0 drives.
        • If the original array contained RAID 1 (ADM) drives, the primary array will contain RAID 1 drives.
        • If the original array contained RAID 10 (ADM) drives, the primary array will contain RAID 1+0 drives.
        • The backup array always contains RAID 0 logical drives.
        • The primary array continues to be fully accessible to the operating system while the backup array is hidden from the operating system.
      • This feature is useful when you want to capture a backup before performing a risky operation. The Manage Split Mirror Backup operation can be used to either re-mirror the primary and backup arrays, or to make the backup array into an independent array which can be accessed by the operating system.
    • Manage Split Mirror Backup
      • This task allows for the management of the primary and backup arrays created by the Create Split Mirror Backup operation. When the operation is performed on a primary array, the following options are available:
        • Re-mirror the array and preserve the existing data. Discard the backup array. This option re-creates the original mirrored array with the contents of the primary array.
        • Re-mirror the array and rollback to the contents of the backup array. Discard existing data. This option re-creates the mirrored array but restores its contents to the point in time when the backup array was created. It is not recommended that this option be performed online, or while the logical drive to be rolled back is mounted or in use by the operating system.
        • Activate the backup array. This option makes the backup array fully accessible to the operating system.

Note: In the case where the primary array is no longer available. This task can only be used to activate the backup array.


Type:Software - System Management
Version:9.40.12.0(19 Feb 2013)
Operating System(s):
Microsoft Windows 7 (64-bit)
Microsoft Windows Server 2003 for 64-bit Extended Systems
Microsoft Windows Server 2008 x64
Microsoft Windows Server 2012
Microsoft Windows Storage Server 2003 x64 Editions
Microsoft Windows Unified Data Storage Server 2003 x64 Edition
Microsoft Windows Vista (64-bit)
Microsoft Windows XP Professional x64 Edition

Description

The HP Array Configuration Utility is a web-based application that helps you configure HP ProLiant SMART-2 Array Controllers, HP ProLiant Smart Array Controllers, HP ProLiant Integrated Smart Array Controllers, and HP ProLiant StorageWorks RAID Array Controllers. You can use the Array Configuration Utility for several tasks such as configuring the array controller initially, adding disk drives to an existing configuration, or to reconfigure your array controller.

Enhancements

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.

Added support for:
HP SmartCache - accelerate data access by using SSD drives as cache
Auto Replace Drive - new spare mode
Full RPI - Rapid Parity Initialization

Installation Instructions

To ensure the integrity of your download, HP recommends verifying your results with this MD5 Checksum value:

cp018121.exe655003c29b4cfcfc29c376aa8d77c6c5

Reboot Requirement:
Reboot is not required after installation for updates to take effect and hardware stability to be maintained.

Installation:
Download the Smart Component to a directory on your hard drive and change to that directory. The downloaded file is a self-extracting executable with a filename based on the Smart Component Number.

From that drive and directory, execute the downloaded file.

Click the 'Install' button to proceed with the installation. The utility will automatically be installed.

Release Notes

End User License Agreements:
Hewlett-Packard End User License Agreement

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.

Notes:
For support for ACU or Smart Array controllers, please visit Contact HP.

For feedback or suggestions on ACU, please send comments to acu@hp.com; however, we regret that support cannot be provided through this address.

The legacy ACU (native win32 application) and ACU executables can not be run on the same server at the same time; however, configurations created with one utility should be compatible with those created by the other.

Users will automatically be logged out after a predetermined period of inactivity when using ACU and will have to re-login.

On the Web-based Management Device Homepage, under 'options', 'Anonymous Access' should be enabled when using ACU.

When clicking on a controller that is currently being configured in a different ACU session, a message will appear which allows you to override the other ACU session or cancel. If you choose to override the other ACU session, any unsaved changes in the other session will be discarded.

To uninstall ACU, use Add/Remove Programs located in the Control Panel on Windows Systems.

To run ACU in local application mode on Windows, Internet Explorer must be the default browser.

The following are known issues:

  • Sometimes the login on the Device Home Page will not work the first time. Click on the Device Home Page link again or refresh the page and re-login.
  • When using Linux as the host operating system, if a Smart Array controller has 16 or more volumes configured, deleting any volume in the ACU will not update the /proc/partitions to reflect the deletion of the device node associated with that volume. Rebooting the server will cause the update to happen. Note that there is also a limitation that only the first 16 volumes configured will be available to the operating system.

Revision History

Version:9.40.12.0(B) (3 May 2013)

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.
Install this 9.40.12.0 (B) version if you require Windows Server 2008 R2. If you have successfully installed 9.40.12.0, then there is no need to install 9.40.12.0 (B).

Added support for:
HP SmartCache - accelerate data access by using SSD drives as cache
Auto Replace Drive - new spare mode
Full RPI - Rapid Parity Initialization


Version:9.40.12.0 (19 Feb 2013)

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.

Added support for:
HP SmartCache - accelerate data access by using SSD drives as cache
Auto Replace Drive - new spare mode
Full RPI - Rapid Parity Initialization


Version:9.30.15.0 (26 Oct 2012)

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.

Logical Drive Movement enhancements


Version:9.20.9.0 (4 Sep 2012)

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.

Support for Smart Array P721m


Version:9.10.22.0 (4 Jun 2012)

Upgrade Requirement:
Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version.

Added support for the following controllers:

  • HP Dynamic Smart Array B120i
  • HP Dynamic Smart Array B320i
  • HP Smart Array P822

Added support for Simplified Chinese
Now officially supporting and providing native X64 versions in addition to existing 32 bit versions
Added new features requiring a valid SAAP 2.0 (Smart Array Advanced Pack) license key:

  • Replace Array
    • Allows the transfer of contents of an array to an existing empty array or a new array. All logical drives from the source array will be transferred. The original array will be deleted and its data drives will be freed as unassigned drives. The drive types at source and destination arrays can be different. This allows moving data from SATA to SAS, or SAS to SATA. However, the drive types comprising the array must still be of the same type.
  • Heal Array
    • Allows the replacement of failed or degraded physical drives in an array with healthy physical drives. The original array and logical drive numbering will be unaffected after the replacement. The replacement physical drives must be of the same interface type (such as SAS, SATA and etc.) as the original drives. The operation will be available only if enough unassigned physical drives of the correct size are available.
  • Spilt Mirror BackupRollback
    • Create Split Mirror Backup
      • This task splits an array that consists of one or more RAID1, RAID 1+0, RAID 1 (ADM), or RAID 10 (ADM) and creates two arrays: A primary array and a backup array. The new arrays have the following characteristics:
        • If the original array contained RAID 1 or RAID 1+0 drives, the primary array will contain RAID 0 drives.
        • If the original array contained RAID 1 (ADM) drives, the primary array will contain RAID 1 drives.
        • If the original array contained RAID 10 (ADM) drives, the primary array will contain RAID 1+0 drives.
        • The backup array always contains RAID 0 logical drives.
        • The primary array continues to be fully accessible to the operating system while the backup array is hidden from the operating system.
      • This feature is useful when you want to capture a backup before performing a risky operation. The Manage Split Mirror Backup operation can be used to either re-mirror the primary and backup arrays, or to make the backup array into an independent array which can be accessed by the operating system.
    • Manage Split Mirror Backup
      • This task allows for the management of the primary and backup arrays created by the Create Split Mirror Backup operation. When the operation is performed on a primary array, the following options are available:
        • Re-mirror the array and preserve the existing data. Discard the backup array. This option re-creates the original mirrored array with the contents of the primary array.
        • Re-mirror the array and rollback to the contents of the backup array. Discard existing data. This option re-creates the mirrored array but restores its contents to the point in time when the backup array was created. It is not recommended that this option be performed online, or while the logical drive to be rolled back is mounted or in use by the operating system.
        • Activate the backup array. This option makes the backup array fully accessible to the operating system.

Note: In the case where the primary array is no longer available. This task can only be used to activate the backup array.